Quantitative sensory testing
Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology
Citation Manager Formats
Make Comment
See Comments

Abstract
Objective: This assessment evaluates the clinical utility, efficacy, and safety of quantitative sensory testing (QST).
Methods: By searching MEDLINE, Current Contents, and their personal files, the authors identified 350 articles. Selected articles utilized computer operated threshold systems, manually operated threshold systems, and electrical threshold devices. The authors evaluated the use of normal values and the degree of reproducibility between the same and different systems. Articles were rated using a standard classification of evidence scheme.
Results: Because of differences between systems, normal values from one system cannot be transposed to others. Reproducibility of results was also an important concern, and there is no consensus on how it should be defined. The authors identified no adequately powered class I studies demonstrating the effectiveness of QST in evaluating any particular disorder. A number of class II and III studies demonstrated that QST is probably or possibly useful in identifying small or large fiber sensory abnormalities in patients with diabetic neuropathy, small fiber neuropathies, uremic neuropathies, and demyelinating neuropathy.
Conclusions: QST is a potentially useful tool for measuring sensory impairment for clinical and research studies. However, QST results should not be the sole criteria used to diagnose pathology. Because malingering and other nonorganic factors can influence the test results, QST is not currently useful for the purpose of resolving medicolegal matters. Well-designed studies comparing different QST devices and methodologies are needed and should include patients with abnormalities detected solely by QST.
- Accepted November 8, 2002.
Disputes & Debates: Rapid online correspondence
- Reply to Letters to the Editor
- Michael E Shy
- Elliott M Frohman
Published June 20, 2003 - Quantitative sensory testing: Report of the Therapeutics and Technology Assessment
- Peter James Dyck
- Peter C O'Brien
Published June 20, 2003 - Quantitative sensory testing: Report of the Therapeutics and Technology Assessment
- Neil I Spielholz
Published June 20, 2003
NOTE: All authors' disclosures must be entered and current in our database before comments can be posted. Enter and update disclosures at http://submit.neurology.org. Exception: replies to comments concerning an article you originally authored do not require updated disclosures.
- Stay timely. Submit only on articles published within the last 8 weeks.
- Do not be redundant. Read any comments already posted on the article prior to submission.
- 200 words maximum.
- 5 references maximum. Reference 1 must be the article on which you are commenting.
- 5 authors maximum. Exception: replies can include all original authors of the article.
- Submitted comments are subject to editing and editor review prior to posting.
You May Also be Interested in
Related Articles
- No related articles found.