Abstract
Objective: To assess prospectively the accuracy and precision of a method for noninvasive intracranial pressure (ICP) measurement compared with invasive gold standard CSF pressure measurement.
Methods: Included were 62 neurologic patients (37 idiopathic intracranial hypertension, 20 multiple sclerosis, 1 Guillain-Barré syndrome, 1 polyneuropathy, and 3 hydrocephalus). The average age was 40 ± 12 years. All patients had lumbar puncture indicated as a diagnostic procedure. ICP was measured using a noninvasive ICP measurement method, which is based on a two-depth high-resolution transcranial Doppler insonation of the ophthalmic artery (OA). The OA is being used as a natural pair of scales, in which the intracranial segment of the OA is compressed by ICP and the extracranial segment of the OA is compressed by extracranial pressure (Pe) applied to the orbit. The blood flow parameters in both OA segments are approximately the same in the scales balance case when Pe = ICP. All patients had simultaneous recording of noninvasive ICP values and invasive gold standard CSF pressure values.
Results: Analysis of the 72 simultaneous paired recordings of noninvasive ICP and the gold standard CSF pressure showed good accuracy for the noninvasive method as indicated by the low mean systematic error (0.12 mm Hg; confidence level [CL] 0.98). The method also showed high precision as indicated by the low SD of the paired recordings (2.19 mm Hg; CL 0.98). The method does not need calibration.
Conclusion: The proposed noninvasive ICP measurement method is precise and accurate compared with gold standard CSF pressure measured via lumbar puncture.
GLOSSARY
- ABP=
- arterial blood pressure;
- CL=
- confidence level;
- ICP=
- intracranial pressure;
- IOA=
- intracranial segment of the internal ophthalmic artery;
- MS=
- multiple sclerosis;
- nICP=
- noninvasive intracranial pressure;
- OA=
- ophthalmic artery;
- TBI=
- traumatic brain injury;
- TCD=
- transcranial Doppler
Footnotes
Study funding: Supported in part by the European Commission under the 7th Framework Programme projects BrainSafe (grant agreement no. 232545) and TBIcare (grant agreement no. 270259).
Supplemental data at www.neurology.org
- Received September 6, 2011.
- Accepted January 25, 2012.
- Copyright © 2012 by AAN Enterprises, Inc.
AAN Members
We have changed the login procedure to improve access between AAN.com and the Neurology journals. If you are experiencing issues, please log out of AAN.com and clear history and cookies. (For instructions by browser, please click the instruction pages below). After clearing, choose preferred Journal and select login for AAN Members. You will be redirected to a login page where you can log in with your AAN ID number and password. When you are returned to the Journal, your name should appear at the top right of the page.
AAN Non-Member Subscribers
Purchase access
For assistance, please contact:
AAN Members (800) 879-1960 or (612) 928-6000 (International)
Non-AAN Member subscribers (800) 638-3030 or (301) 223-2300 option 3, select 1 (international)
Sign Up
Information on how to subscribe to Neurology and Neurology: Clinical Practice can be found here
Purchase
Individual access to articles is available through the Add to Cart option on the article page. Access for 1 day (from the computer you are currently using) is US$ 39.00. Pay-per-view content is for the use of the payee only, and content may not be further distributed by print or electronic means. The payee may view, download, and/or print the article for his/her personal, scholarly, research, and educational use. Distributing copies (electronic or otherwise) of the article is not allowed.
Disputes & Debates: Rapid online correspondence
- Response to Miller et al.
- A. Ragauskas, Kaunas University of Technology, Kaunas, Lithuaniatelematics@ktu.lt
- V. Matijosaitis (Kaunas, Lithuania), R. Zakelis (Kaunas, Lithuania), K. Petrikonis (Kaunas, Lithuania), D. Rastenyte (Kaunas, Lithuania), I. Piper (Glasgow), G. Daubaris (Kaunas, Lithuania)
Submitted September 07, 2012 - Response Liebeskind et al.
- A. Ragauskas, Kaunas University of Technology, Kaunas, Lithuania, telematics@ktu.lt
- V. Matijosaitis (Kaunas, Lithuania), R. Zakelis (Kaunas, Lithuania), K. Petrikonis (Kaunas, Lithuania), D. Rastenyte (Kaunas, Lithuania), I. Piper (Glasgow), G. Daubaris (Kaunas, Lithuania)
Submitted September 07, 2012 - Blood flow velocities are reduced in the optic nerve with elevated intracranial pressure
- Marijean M. Miller MD, Attending, Pediatric Ophthalmology and Director, Neonatal Ophthalmology, Associate Professor of Oph, Children's National Medical Center and The George Washington Universitymj.miller1@verizon.net
- Taeun Chang, MD Director, Neonatal Neurology Division, Neurophysiology & Epilepsy; Robert Keating, MD Professor and Chief Department of Neurosurgery; Craig Sable, MD Director, Echocardiography and Telemedicine, Professor of Pediatrics
Submitted July 05, 2012 - Pressure On The Orbit Does Not Balance Transmural Pressure In The Segments Of Ophthalmic Artery
- David S. Liebeskind, Physician, Los Angeles, CAopranevicius@aol.com
- E.Marcinkevicius, Kaunas, Lithuania; M.Pranevicius NY,NY; O.Pranevicius NY,NY
Submitted June 20, 2012 - A noninvasive intracranial pressure absolute value measurement method: promising in understanding hyper-perfusion syndrome
- Yingkun He, Dr., Henan Provincial Pepole's Hospital, Zhengzhou University; and the First Affiliated Hospital of Zhengheyingkun@126.com
- Interventional Department of Henan Provincial people's Hospital, Zhengzhou University, No.7 Weiwu Road, Zhengzhou, 450003, China;
Submitted May 25, 2012
NOTE: All authors' disclosures must be entered and current in our database before comments can be posted. Enter and update disclosures at http://submit.neurology.org. Exception: replies to comments concerning an article you originally authored do not require updated disclosures.
- Stay timely. Submit only on articles published within 6 months of issue date.
- Do not be redundant. Read any comments already posted on the article prior to submission.
- 200 words maximum.
- 5 references maximum. Reference 1 must be the article on which you are commenting.
- 5 authors maximum. Exception: replies can include all original authors of the article.
- Submitted comments are subject to editing and editor review prior to posting.