Artifact-related epilepsy
Citation Manager Formats
Make Comment
See Comments

This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
Abstract
Potentials that do not conform to an expected electrical field generated by the brain characterize an extracerebral source or artifact. Artifact is present in virtually every EEG. It is an essential component for routine visual analysis, yet it may beguile the interpreter into falsely identifying waveforms that simulate epileptiform discharges (ED). The principal importance of artifact is represented by the frequency of its occurrence in contrast to the limited frequency of normal variants that may imitate pathologic ED. Continuous EEG monitoring has uncovered newly identified artifacts unique to prolonged recording. The combined use of video and EEG has revolutionized our ability to distinguish cerebral and extracerebral influences through behavioral correlation that is time-locked to the electrophysiologic features that are present on EEG. Guidelines exist to ensure minimal standards of recording. Precise definitions are present for ED. Still, the ability to distinguish artifact from pathologic ED requires a human element that is to provide the essential identification of an abnormal EEG. The ramification of a misinterpreted record carries an acute risk of treatment and long-term consequences for diagnosis-related harm.
Glossary
- cEEG=
- continuous EEG;
- ED=
- epileptiform discharges;
- EMU=
- epilepsy monitoring unit;
- ICA=
- independent component analysis;
- ICU=
- intensive care unit;
- PNEA=
- psychogenic nonepileptic attacks;
- PWS=
- patients with seizures;
- vEEG=
- video EEG
Footnotes
Go to Neurology.org for full disclosures. Disclosures deemed relevant by the authors, if any, are provided at the end of this article.
- Received November 16, 2011.
- Accepted February 29, 2012.
- © 2012 American Academy of Neurology
AAN Members
We have changed the login procedure to improve access between AAN.com and the Neurology journals. If you are experiencing issues, please log out of AAN.com and clear history and cookies. (For instructions by browser, please click the instruction pages below). After clearing, choose preferred Journal and select login for AAN Members. You will be redirected to a login page where you can log in with your AAN ID number and password. When you are returned to the Journal, your name should appear at the top right of the page.
AAN Non-Member Subscribers
Purchase access
For assistance, please contact:
AAN Members (800) 879-1960 or (612) 928-6000 (International)
Non-AAN Member subscribers (800) 638-3030 or (301) 223-2300 option 3, select 1 (international)
Sign Up
Information on how to subscribe to Neurology and Neurology: Clinical Practice can be found here
Purchase
Individual access to articles is available through the Add to Cart option on the article page. Access for 1 day (from the computer you are currently using) is US$ 39.00. Pay-per-view content is for the use of the payee only, and content may not be further distributed by print or electronic means. The payee may view, download, and/or print the article for his/her personal, scholarly, research, and educational use. Distributing copies (electronic or otherwise) of the article is not allowed.
Letters: Rapid online correspondence
REQUIREMENTS
You must ensure that your Disclosures have been updated within the previous six months. Please go to our Submission Site to add or update your Disclosure information.
Your co-authors must send a completed Publishing Agreement Form to Neurology Staff (not necessary for the lead/corresponding author as the form below will suffice) before you upload your comment.
If you are responding to a comment that was written about an article you originally authored:
You (and co-authors) do not need to fill out forms or check disclosures as author forms are still valid
and apply to letter.
Submission specifications:
- Submissions must be < 200 words with < 5 references. Reference 1 must be the article on which you are commenting.
- Submissions should not have more than 5 authors. (Exception: original author replies can include all original authors of the article)
- Submit only on articles published within 6 months of issue date.
- Do not be redundant. Read any comments already posted on the article prior to submission.
- Submitted comments are subject to editing and editor review prior to posting.
You May Also be Interested in
Hastening the Diagnosis of Amyotrophic Lateral Sclerosis
Dr. Brian Callaghan and Dr. Kellen Quigg
► Watch
Related Articles
Topics Discussed
Alert Me
Recommended articles
-
How not to read an EEG
Pitfalls in ictal EEG interpretationCritical care and intracranial recordingsNicolas Gaspard, Lawrence J. Hirsch et al.Neurology, December 24, 2012 -
How not to read an EEG
Normal “suspicious” EEGWilliam O. Tatum et al.Neurology, December 24, 2012 -
Articles
Electrographic seizures and periodic discharges after intracerebral hemorrhageJ. Claassen, N. Jetté, F. Chum et al.Neurology, September 24, 2007 -
Article
Continuous EEG in therapeutic hypothermia after cardiac arrestPrognostic and clinical valueAmy Z. Crepeau, Alejandro A. Rabinstein, Jennifer E. Fugate et al.Neurology, January 02, 2013