Objective: The purpose of this study was to determine accuracy of a commercially available device to estimate sleep stages.
Background: Although many wearables purport to accurately distinguish between light and deep sleep, little information on the validity of using wearables in this manner is available.
Design/Methods: Overnight recordings were made on 55 individuals wearing a Garmin wearable device (vivosmart 3) on the nondominant wrist. EEG data was simultaneously collected using a take home device (Sleep Profiler) that recorded three channel EEG for sleep staging. EEG data was scored by a Registered Polysomnographic Technologist using AASM guidelines. An automated algorithm to distinguish sleep stages (wake, light (N1 and N2), deep, and REM was developed using a neural network approach.
Results: Of the 55 participants, 31% (17) were female and 69% were (38) male. (Age 35.5 +/− 8.7 years old; BMI 26.3 +/− 6.4) Per epoch accuracy of 69.7% was achieved, with a Cohen’s kappa of 0.54 +/− 0.12. A sleep sensitivity of 95.8% and a wake specificity of 73.4% was obtained.
Conclusions: This study demonstrates that a wearable device employing optical PPG and accelerometry signals is a valid method to estimate sleep stages in a cohort of young adults.
Disclosure: Dr. Stevens has received personal compensation for consulting, serving on a scientific advisory board, speaking, or other activities with Jazz Pharmaceuticals and Inspire. Dr. Stevens has received research support from Garmin. Dr. Siengsukon has received personal compensation for consulting, serving on a scientific advisory board, speaking, or other activities with Evidence in Motion and PT Management Support Systems.
Disputes & Debates: Rapid online correspondence
NOTE: All authors' disclosures must be entered and current in our database before comments can be posted. Enter and update disclosures at http://submit.neurology.org. Exception: replies to comments concerning an article you originally authored do not require updated disclosures.
- Stay timely. Submit only on articles published within the last 8 weeks.
- Do not be redundant. Read any comments already posted on the article prior to submission.
- 200 words maximum.
- 5 references maximum. Reference 1 must be the article on which you are commenting.
- 5 authors maximum. Exception: replies can include all original authors of the article.
- Submitted comments are subject to editing and editor review prior to posting.
You May Also be Interested in
Related Articles
- No related articles found.